HomeMy WebLinkAboutDrain Layers Permit 1 Bidwell Road ,Qiu JCL o FC9 Fe �i�/e.nR c fR��,gc bruary 22.E 1971
RD .
List No,,
Dear Sirs
For your co 6nvenience a the Sewer Co mission of the
Town of South Windsor permitted connection of the
below-described property to the sewer system prior to
establishmat o': a schedule of charges ,,
This sched tle is now completed and adopted and the
connection char,,es are.-
Resident-',alp- n. 4400.00 per unit
Other th; n Residential.: $1,,000.00 per acre
Your conne, tion charge has been computed and is
shown below„ T1,,is amount is due and payable on
April 181971..
If you have. any questions, please call the Super-
intendent of tt a Department of Pollution Control v
289-0185 or 644—2511
Permit No /
Number of Units (Residential) Caraection Crge $ �
Number of Acres (Other than Res„ ,.S' Convection. Charge $fib ,
s
Very truly ,yours.
TOWN OF SOUTB WINDSOR
r
Richard Reeves,, Chairman
South Windsor Sewer Commission
FOR
SANITARY SEWER SERVICE
Town of South Windsor, 1540 Sullivan Avenue 6441511
13k'partmnti Of POD .ution Control Vibert, Road,, South Windsor, 28.9-0185
vAtals T"tuls
Occupant St l AU030 E. & Paton G. & A,ecount No 04*30U9
Addre is
_ , - # 13
M F
p Block Parcel Parcel�. 41E
V aage uacct�pri
Ai-isa ., +► r_� Acres "`v., . ®..-
Sketch
(Not to Scale)
E.
A Foot Assessment 9.50 q� 3*703 00
vv
al Assessment 20.0;
Total Assessment 3*905*00
see=smente Due Date
: erred Yes N
Caveat. Fij*:d Ye.1 N . a.,
Paid in Full Yes .�.�.
To be paid in steal.l nts Yes .� �..a...��
9 A I".1a l PayA I?ts of +*.7a�•"�M
— �lws %m
on unpaid balance "
Liam Filed Yes
Connection, �s' Coo ut:t3tj-0-n'f-.�., �....� o
S.�F,' 4.�i:r 1 ;T} 'a t✓'+YS{\-.� - 'Ll.{. CsLl'. rcl �
�...��. X Unit COnnect1,nn Charge $y
..._ ,X Area Connect:ion Charge$I,tip•00 z-_q.1*xw4OO
Date
Toum Cngincer
a
qq
44T i ijjl Lr
i� }' -
�I hid
-
$'+.°.� ,�'ki Town Hall, 1540 Sullivan Avenue, South Windsor, Connecticut 06074
POLLUTION CONTROL DEPARU',EliT 29 June, 1973
I eta is Testing CompC�y, Inc.
1 Bidwell Road, P.O. Box No. 213
South Wixdsor, Connecticut 06074
Attention: Mr. Frzank W. Dunn...Vice President/General Mamager
Dear Mr. Dunn:
In response to your letter of 25 Mz y to Mr. Harvey W. Levack, forrser
SuperiAte de zt of the Pollution Control Departmc t, and our teleprome talk of
ycsterdRy afternoor, I m pleased to forward the following.
Please consider thin letter as recoAfirpomtion of.:P.pprovt_l from the Tow?
of South Wir�dsor for kic^tals Testing to dispose of wash wttter cortairirg
fluorescent peActrm rt (t1'yglo"} i� ,�x,cctio» materials into the South 4di d.or
sr�it�.ry se��rc�r systems.
I trust that the above ricets With your approval. Should you have any
questions, or desire additional ir-formation, please feel free to coxtact me
-.t any time.
Very truly yours,
TOWNI OF SOUTH WINDSOR
AOL
M;l C, , wards, Jr. '
Superintendent, Pollution Control
cc: E.W. Lucek
file
1 v�'�• O (203) 289 - 8225
ACCREDITED NONDESTRUCTIVE TESTING
1 BIDWELL ROAD&JOHN PITCH BLVD. • P.O.BOX 213 • SOUTH WINDSOR,CONNECTICUT 06074
May 25, 1973
Mr, Harvey Levack
Superintendent, Sewer Dept,
Town Hall
1540 Sullivan Ave
South Windsor Conn 06074
Dear Mr. Levack:
The Metals Testing Co, requests reconfirmation of its approval- ,-
to dispose of wash water containing fluorescent penetrant
("Zyglo") inspection materials into the South Windsor sanitary
sewer system. This has been our practice ever since the
Metals Testing Co, moved to South Windsor four and one-half
years ago.
The fluorescent penetrant material as it goes into the wash
station in our plant, consists of an oily substance mixed
with an emulsifying agent. When washed with water, this forms
a very dilute emulsion which goes into the drain to the sanitary
sewer. The total volume of the oily substance varies from
one-half gallon to one gallon per day. This oil-emulsifier
mixture is diluted in the washing process with more than two
thousand gallons of water. As for toxicity, we have certifications
from the manufacturer of the penetrant materials that they are
nontoxic and meet all the requirements of the specification
MIL-STD-251350
Occasionally, but rarely, we have to dispose of some quantities
of used oily material in bulk. These will be accumulated in
steel drums and removed from our premises by the Connecticut
Waste Oil Co. in Tracy, Conn,
By following the procedures outlined above, we believe that we
will be operating to the satisfaction of the South Windsor Sewer
Department and the Connecticut Environmental Protection Agency.
Yours Very Truly,
Me�--�Te Ling Co., Inc.
"3,9
Frank
Vice President/General Manager